Below you will find Attension instructional videos
Theta
3D Topography module calibration
Sigma
Below you will find Attension instructional videos
Theta
3D Topography module calibration
Sigma
OneAttension Release Notes (pdf)
Service and Support
Biolin Scientific systems are precision instruments, providing accurate and reliable results. To ensure that your instrument maintains peak performance, we offer a number of service and support solutions, see more information further below.
If you have a technical problem with …
OneAttension users can download the latest software update using the link below. Updating is highly recommended for all OneAttension users since updates include important bug fixes and may bring new functionality compared to prior versions. The new package can be simply installed on top of an …
Biolin Scientific systems are precision instruments, providing accurate and reliable results. To ensure that you and your instrument maintain peak performance, we offer a number of service and support solutions.
For application and software support, please contact support@q-sense.com.
For service …
Training will help you get the most out of your QSense instrument. Our educational range aims to get you comfortable in the laboratory so that you can discover the many ways QCM-D can bring your research forward. By offering assistance and education on data analysis and data modelling we also help …
To learn more, please our recorded Dfind training webinars here.
With several analysis examples, Malin Edvardsson, one of our Dfind experts, will guide you through the main features and functions of the software, and demonstrate how they can be used.
Supporting You with Application and Technical Services
We provide support through a global network of highly competent Distribution Partners and a team of Application and Technical Support Specialists based in Biolin Scientific offices in Europe, Asia and North America.
We offer installation, …
Operator Manual
Operator Manual
Langmuir and Langmuir-Blodgett Deposition Troughs
Langmuir and Langmuir-Blodgett Modules and Accessories
Polarization Modulation Infrared Reflection Absorption Spectrometer PM-IRRAS
Attension Sigma 702ET Manual Rev 1.19
User Instruction
Quick Start Guide
Operator Manual EdAI
Operator Manual Chinese
Quick Start Guide
Operator Manual EdAI
Operator Manual Chinese
Operator Manual
Method Description by Ralf P. Richter For Ismatec pump user manuals, see external link:
Operator Manual
Operator Manual
Operator Manual
Operator Manual EdA
Enzymatic Degradation of Lipid Films Caused by Lipase
Structural Change of Adsorbed Protein Layer
Analyzing Surface Induced Complement Activation
Early Detection of Biofilm Formation on Steel Surface
The QCM-D Technology To Study Surfactant/Surface Interactions
ISR User Manual Revision 3.5
PM-IRRAS User Manual Revision 1.2
Cabinet Assembly
Julabo F12-ED Water Bath Connections Setup Guide
Julabo F12-MC Water Bath Setup Guide
Julabo CD 200F Water Bath with LB and DC Software Setup Guide
KN0013 User Note
Vacuum pump Setup Instructions
DipCoater Extra Large Set-up guide
DipCoater Multi Vessel Large and Medium Quick Start
DipCoater Multi Vessel
Small Mechanical Installation Guide
Dip Coater Single Vessel
Mechanical Installation Guide
Dip Coater Single Vessel Large and Medium Mechanical Installation Guide
Dip Coaters User Manual
LB
LB Medium Accessories Setup Guide v.1
LB Medium Setup Guide v.1
Langmuir and Langmuir-Blodgett systems All Models Installation Manual v 1.3
Langmuir and Langmuir-Blodgett devices All Models Software Manual v 1.7
Ribbon Barrier Manual v 1.1
MicroBAM Manual Revision 1.4
Interactions of Biomolecules in Cell Membrane Models
Polarization Modulated Infrared Spectroscopy of Thin Films at the Nanometer Scale
Deposition and Characterization of Single-Sheet Graphene and Graphene Oxide Films
Absorption and Interfacial Gelation of Proteins at Air-Water and Oil-Water Interface
Contact Angle Measurements on Single Fibers
Tensiometry in Inkjet Printing Applications
Influence of Contact Angles and Surface Free Energies on Biocompatibility of Biomaterials
Critical Micelle Concentration Measurement in Aggregation Behavior Studies Wettability of …
Static and Dynamic Contact Angles and Their Measurement Techniques
Surface and interfacial tension and their measurement techniques
Critical Micelle Concentration — Theory and Measurement
Surface Free Energy — Theory and Calculations
Washburn Method 6. Influence of Droplet Volume on Contact Angle
What kinds of samples are suitable for topography studies?
What size droplets can be made with Theta?
What are the differences between using a Wilhelmy plate or a Du Noüy ring in surface / interfacial tension measurements?
How should I clean a Wilhelmy plate?
How should I clean a Du Noüy ring?
What kinds of samples are suitable for powder wettability studies?
What is the viscosity range of liquids that …
What is the difference between QCM-D and traditional QCM?
What is dissipation?
Why is it important to measure the energy dissipation?
How is the sensitivity distributed over the crystal surface?
What is the difference between QCM-D and SPR measurements?
What is the surface roughness of the sensors?
What is the active area of the sensor for each different overtone?
What coatings/surfaces can be used?
When is the adsorption layer considered as rigid enough for the Sauerbrey relation to be valid?
What is the maximum thickness of a polymer layer that can …
What is the mass sensitivity of Q-Sense instruments?
What is the frequency range of Q-Sense instruments?
What are the benefits of taking measurements at several frequencies simultaneously?
What is the exact detection range into the medium above the sensor?
What is the maximum thickness of an …
How do I perform a standard isotherm experiment with a liquid-liquid trough?
How should I clean the Wilhelmy plate?
How should I clean my trough and barriers?
Paints, pharmaceuticals, cosmetics, food, textiles, composites and filters are based on absorptive properties of powders, particles and fibers as well as porous materials. Moreover, the wettability of powders, particles, fibers and porous materials plays a very important role in the quality, …
Benjamin Franklin’s report to the British Royal Society in 1774 is a good starting point for the history of Langmuir or Langmuir-Blodgett films. In his report Franklin stated:
“At length at Clapham where there is, on the common, a large pond, which I observed to be one day very rough with the wind, …
Adhesion is the attraction between two dissimilar phases. Current theory divides adhesion into the three categories: fundamental adhesion, practical adhesion and thermodynamic adhesion.
Langmuir-Blodgett technology enables the deposition of single- or multimolecular layers from a liquid surface onto a solid substrate with excellent film structure control. LB is especially well suited for creating highly organized nanoparticle coatings, for example.
Langmuir-Blodgett film (or LB …
Controlling the adsorption or rejection of certain types of materials at solid surfaces or liquid interfaces is very important for numerous applications, such as biocompatible surfaces, sensor technologies, cleaning processes as well as emulsion and foam stability.
Adsorption of materials to solid …
A Langmuir film can be defined as an insoluble spread monolayer of atoms or molecules floating at the liquid-gas interface (or liquid-liquid). Monolayer formation is possible due to the forces of self-assembly on insoluble molecules at the surface of a liquid.
Amphiphilic monolayers are the most …
Optimal cleanliness plays an important part in many application segments, e.g. preparation and processing of silicon wafers for semiconductor industry, and packaging materials for food and pharmaceutical products. Cleanliness control is also essential in food factories, hospitals and in process …
A microscopy trough is a special kind of Langmuir trough for characterization of Langmuir films before, during and after fabrication.
A microscopy trough is a special kind of Langmuir trough that includes a sapphire window in the top base of the PTFE trough that allows high optical transmission …
Force tensiometry is a powerful and accurate technique to measure static surface tension and interfacial tension of liquids. These direct measurements allow determination of material and surface properties, such as dynamic contact angle, surface free energy.
Force tensiometry provides information …
Langmuir-Schaefer film (or LS film) can be defined as one or more monolayers of material deposited from a liquid surface onto a solid substrate. The deposition can be made by dipping the substrate horizontally through a floating monolayer at a constant molecular density or by placing the substrate …
Contact angle hysteresis is the difference between the maximum (advancing) and minimum (receding) contact angles. The significance of hysteresis has been the object of much research and can be used to help characterize chemical heterogeneity, roughness and mobility.
Contact angle, θ, is a …
A monolayer is a single-molecule thick film or layer of closely packed atoms or molecules at an interface. Monolayers are often formed at the air-water interface as a Langmuir film. Monolayers are often located on a solid surface or floating on a gas-liquid interface. However, some monolayers can …
Optical tensiometry is a versatile technique used to characterize material surface properties and interfacial interactions between gas, liquid and solid phases. Optical tensiometers are used in R&D and quality control in a variety of industries, including biomaterials, chemicals, pharmaceuticals, …
In the context of a Langmuir film, surface pressure is the difference in surface tension measured between a clean sub-phase and a monolayer-covered sub-phase. Surface pressure greatly influences monolayer properties.
Monolayers and surface pressure
Substances that can form monolayers are often …
Dynamic wetting of liquid on a solid surface can be divided into a spreading and absorption that can both be followed by contact angle measurements. Knowing the spreading rate is essential in many application segments, for example in the textile industry, coating and ink development and in …
Surface pressure—area isotherm or π-A isotherm can be defined as a measurement at constant temperature of surface pressure, as a function of the available area for each molecule in a floating monolayer (Langmuir film).
The most important indicator of the monolayer properties of an amphiphilic …
Typically, coatings and surface treatments should be homogeneously distributed over the whole surface that they applied to, and at times surface heterogeneity can be a desirable characteristic. After applying any coating or surface treatment, heterogeneity control can be performed by contact …
Wettability or wetting is the process that occurs when a liquid spreads and/or absorbs on a solid substrate or material. Wettability can be estimated by measuring the contact angle or by calculating the spreading coefficient.
Examples of where solid surface wettability plays a crucial role include: …