Start Publications Improved antibacterial behavior of titanium surface with ...
Attension

Improved antibacterial behavior of titanium surface with torularhodin-polypyrrole film

Year: 2014

Journal: MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, Vol. 42, p 726-733, 20150722

Authors: Ungureanu, Camelia; Popescu, Simona; Purcel, Gabriela; Tofan, Vlad; Popescu, Marian; Salageanu, Aurora; Pirvu, Cristian

Organizations: Polytech Univ, Bucharest 011061, Romania; Natl Inst Res & Dev Microtechnol, Bucharest 077190, Romania; Cantacuzino Natl Inst Res Dev Microbiol & Immunol, Bucharest 050096, Romania

The problem of microorganisms attaching and proliferating on implants and medical devices surfaces is still attracting interest in developing research on different coatings based on antibacterial agents. The aim of this work is centered on modifying titanium (Ti) based implants surfaces through incorporation of a natural compound with antimicrobial effect, torularhodin (T), by means of a polypyrrole (PPy) film. This study tested the potential antimicrobial activity of the new coating against a range of standard bacterial strains: Escherichia coli, Staphylococcus aureus, Enterococcus faecalis, Bacillus subtilis and Pseudomonas aeruginosa. The morphology, physical and electrochemical properties of the synthesized films were assessed by SEM, AFM, UV-Vis, FTIR and cyclic voltammetry. In addition, biocompatibility of this new coating was evaluated using L929 mouse fibroblast cells. The results showed that PPy-torularhodin composite film acts as a corrosion protective coating with antibacterial activity and it has no harmful effect on cell viability. (C) 2014 Elsevier B.V. All rights reserved.