Start Publications Platelet adhesion on silicon modified hydrogenated amorphous ...
Attension

Platelet adhesion on silicon modified hydrogenated amorphous carbon films

Year: 2004

Journal: Biomaterials 25 (2004) 239-245, 20111221

Authors: T.I.T. Okpalugo, A.A. Ogwu, P.D. Maguire, J.A.D. McLaughlin

Organizations: NIBEC, School of Electrical and Mechanical Engineering, University of Ulster, Shore road, BT37 OQB Northern Ireland, UK

We have investigated the effect of changes in microstructure, surface energy, surface charge condition and electronic conduction on the interaction of human platelets with silicon modi.ed hydrogenated amorphous carbon films (a-C:H:Si or Si-DLC).Results based on Raman spectroscopy, Scanning electron microscopy, Xray photo-electron spectroscopy, surface energy measurements, electrical resistivity, contact potential difference, and thermal annealing indicates a correlation between some of the measured values and the interaction of the films with human blood platelets. Statistical analysis of platelet aggregation on the films using the Student's t-test indicated differences between platelet aggregation on the modified films compared to the as-deposited film at a ρ-value of <0.05.