Start Publications Polythiophene-g-poly(ethylene glycol) graft copolymers for ...
Attension

Polythiophene-g-poly(ethylene glycol) graft copolymers for electroactive scaffolds

Year: 2013

Journal: J. Mater. Chem. B, 2013,1, 4135-4145, 20131119

Authors: Anca-Dana Bendrea 1 2, Georgina Fabregat 2 3, Juan Torras 4, Silvana Maione 2 3, Luminita Cianga 1, Luis J. del Valle 2, Ioan Cianga *1 and Carlos Alemán * 2 3

Organizations: 1: “Petru Poni” Institute of Macromolecular Chemistry, 41A, Grigore–Ghica Voda Alley, Iasi, Romania, 2: Departament d'Enginyeria Química, E. T. S. d'Enginyers Industrials, Universitat Politècnica de Catalunya, Diagonal 647, 08028 Barcelona, Spain, 3: Center for Research in Nano-Engineering, Universitat Politècnica de Catalunya, Campus Sud, Edifici C', C/Pasqual i Vila s/n, Barcelona E-08028, Spain, 4: Department of Chemical Engineering, Igualada School of Engineering, Universitat Politècnica de Catalunya, Pça Rei 15, Igualada 08700, Spain

The properties, microscopic organization and behavior as the cellular matrix of an all-conjugated polythiophene backbone (PTh) and well-defined poly(ethylene glycol) (PEG) grafted chains have been investigated using different experimental techniques and molecular dynamic simulations. UV-vis spectroscopy has been used to determine the optical band gap, which has been found to vary between 2.25 and 2.9 eV depending on the length of the PEG chains and the chemical nature of the dopant anion, and to detect polaron → bipolaron transitions between band gap states. The two graft copolymers have been found to be excellent cellular matrices, their behavior being remarkably better than that found for other biocompatible polythiophene derivatives [e.g. poly(3,4-ethylenedioxythiophene)]. This is fully consistent with the hydrophilicity of the copolymers, which increases with the molecular weight of the PEG chains, and the molecular organization predicted by atomistic molecular dynamics simulations. Graft copolymers tethered to the surface tend to form biphasic structures in solvated environments (i.e. extended PTh and PEG fragments are perpendicular and parallel to the surface, respectively) while they collapse onto the surface in desolvated environments. Furthermore, the electrochemical activity and the maximum of current density are remarkably higher for samples coated with cells than for uncoated samples, suggesting multiple biotechnological applications in which the transmission with cells is carried out at the electrochemical level.